• Tabela de Variação Milivoltagem do Termopar Platina Ródio 13% – Platina tipo R (PtPtRh13%) na faixa +1060°C à +1429°C

Tabela de Variação Milivoltagem do Termopar Platina Ródio 13% - Platina tipo R (PtPtRh13%) na faixa +1060°C à +1429°C

Milivoltagem Termopar PtPtRh13% +1060/+1429°C

°C0123456789
106011,30711,32111,33411,34811,36111,37511,38811,40211,41511,429
107011,44211,45611,46911,48311,49611,51011,52411,53711,55111,564
108011,57811,59111,60511,61811,63211,64611,65911,67311,68611,700
109011,71411,72711,74111,75411,76811,78211,79511,80911,82211,836
110011,85011,86311,87711,89111,90411,91811,93111,94511,95911,972
111011,98612,00012,01312,02712,04112,05412,06812,08212,09612,109
112012,12312,13712,15012,16412,17812,19112,20512,21912,23312,246
113012,26012,27412,28812,30112,31512,32912,34212,35612,37012,384
114012,39712,41112,42512,43912,45312,46612,48012,49412,50812,521
115012,53512,54912,56312,57712,59012,60412,61812,63212,64612,659
116012,67312,68712,70112,71512,72912,74212,75612,77012,78412,798
117012,81212,82512,83912,85312,86712,88112,89512,90912,92212,936
118012,95012,96412,97812,99213,00613,01913,03313,04713,06113,075
119013,08913,10313,11713,13113,14513,15813,17213,18613,20013,214
120013,22813,24213,25613,27013,28413,29813,31113,32513,33913,353
121013,36713,38113,39513,40913,42313,43713,45113,46513,47913,493
122013,50713,52113,53513,54913,56313,57713,59013,60413,61813,632
123013,64613,66013,67413,68813,70213,71613,73013,74413,75813,772
124013,78613,80013,81413,82813,84213,85613,87013,88413,89813,912
125013,92613,94013,95413,96813,98213,99614,01014,02414,03814,052
126014,06614,08114,09514,10914,12314,13714,15114,16514,17914,193
127014,20714,22114,23514,24914,26314,27714,29114,30514,31914,333
128014,34714,36114,37514,39014,40414,41814,43214,44614,46014,474
129014,48814,50214,51614,53014,54414,55814,57214,58614,60114,615
130014,62914,64314,65714,67114,68514,69914,71314,72714,74114,755
131014,77014,78414,79814,81214,82614,84014,85414,86814,88214,896
132014,91114,92514,93914,95314,96714,98114,99515,00915,02315,037
133015,05215,06615,08015,09415,10815,12215,13615,15015,16415,179
134015,19315,20715,22115,23515,24915,26315,27715,29115,30615,320
135015,33415,34815,36215,37615,39015,40415,41915,43315,44715,461
136015,47515,48915,50315,51715,53115,54615,56015,57415,58815,602
137015,61615,63015,64515,65915,67315,68715,70115,71515,72915,743
138015,75815,77215,78615,80015,81415,82815,84215,85615,87115,885
139015,89915,91315,92715,94115,95515,96915,98415,99816,01216,026
140016,04016,05416,06816,08216,09716,11116,12516,13916,15316,167
141016,18116,19616,21016,22416,23816,25216,26616,28016,29416,309
142016,32316,33716,35116,36516,37916,39316,40716,42216,43616,450

Milivoltagem Termopar PtPtRh13% +1060/+1429°C

Como devemos fazer a consultar na tabela termopar (Temperatura x milivoltagem)?
Primeiramente devemos escolher a tabela com a temperatura que queremos consultar.
Em segundo lugar localizar na tabela a temperatura desejada na primeira coluna (°C). Essa coluna possui as temperatura de 10°C em 10°C sendo as unidades dispostas na primeira linha da coluna. Essa linha temos a divisão da temperatura de 1°C em 1°C.

Vamos supor um exemplo: Queremos saber qual a milivoltagem de um termopar na temperatura de 153°C e 78°C. Importante lembrar que a tabela abaixo possui valores genéricos e está neste exemplo apenas para mostrar com devemos fazer a consulta.
Basta procura na coluna a esquerda as temperaturas de 150°C e 70°C e deslizar sobre a linha de cada uma destas temperaturas até chegar na unidade desejada. No caso da temperatura de 153°C deslizar sobre a linha do valor de 150°C até chegar ao valor da coluna 3 que representa o valor de 153°C que queremos. A mesma coisa para a temperatura de 78°C; deslizar sobre a linha do valor de 70°C até chegar na coluna 8 que representa o valor de 78°C.

Tabela de Variação Milivoltagem do Termopar Platina Ródio 13% - Platina tipo R (PtPtRh13%) na faixa +1060°C à +1429°C

Visite no YouTube o Curso Termometria Instrumentação Industrial.